NFSv4 C. Hellwig Internet-Draft Intended status: Informational July 08, 2016 Expires: January 9, 2017 Using the Parallel NFS (pNFS) SCSI Layout with NVMe draft-hellwig-nfsv4-scsi-layout-nvme-00.txt Abstract This document explains how to use the Parallel Network File System (pNFS) SCSI Layout Type with transports using the NVMe or NVMe over Fabrics protocol. Status of This Memo This Internet-Draft is submitted in full conformance with the provisions of BCP 78 and BCP 79. Internet-Drafts are working documents of the Internet Engineering Task Force (IETF). Note that other groups may also distribute working documents as Internet-Drafts. The list of current Internet- Drafts is at http://datatracker.ietf.org/drafts/current/. Internet-Drafts are draft documents valid for a maximum of six months and may be updated, replaced, or obsoleted by other documents at any time. It is inappropriate to use Internet-Drafts as reference material or to cite them other than as "work in progress." This Internet-Draft will expire on January 9, 2017. Copyright Notice Copyright (c) 2016 IETF Trust and the persons identified as the document authors. All rights reserved. This document is subject to BCP 78 and the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info) in effect on the date of publication of this document. Please review these documents carefully, as they describe your rights and restrictions with respect to this document. Code Components extracted from this document must include Simplified BSD License text as described in Section 4.e of the Trust Legal Provisions and are provided without warranty as described in the Simplified BSD License. Hellwig Expires January 9, 2017 [Page 1] Internet-Draft pNFS SCSI Layout for NVMe July 2016 Table of Contents 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . 2 1.1. Conventions Used in This Document . . . . . . . . . . . . 2 1.2. General Definitions . . . . . . . . . . . . . . . . . . . 2 2. SCSI Layout mapping to NVMe . . . . . . . . . . . . . . . . . 3 2.1. Volume Identification . . . . . . . . . . . . . . . . . . 3 2.2. Client Fencing . . . . . . . . . . . . . . . . . . . . . 3 2.3. Volatile write caches . . . . . . . . . . . . . . . . . . 3 3. Security Considerations . . . . . . . . . . . . . . . . . . . 4 4. IANA Considerations . . . . . . . . . . . . . . . . . . . . . 4 5. Normative References . . . . . . . . . . . . . . . . . . . . 4 Author's Address . . . . . . . . . . . . . . . . . . . . . . . . 4 1. Introduction The pNFS SCSI layout [scsi-layout] is a layout type that allows NFS clients to directly perform I/O to block storage devices while bypassing the MDS. It is specified by using concepts from the SCSI protocol family for the data path to the storage devices. This documents explains how to access PCI Express, RDMA or Fibre Channel devices using the NVM Express protocol [NVME] using the SCSI layout type by leveraging the SCSI Translation Reference ([NVME-STLR]). This document does not amend the pNFS SCSI layout document in any way, instead of explains how to map the SCSI constructs used in the pNFS SCSI layout document to NVMe concepts using the NVMe SCSI translation reference. 1.1. Conventions Used in This Document The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this document are to be interpreted as described in [RFC2119]. 1.2. General Definitions The following definitions are provided for the purpose of providing an appropriate context for the reader. Client The "client" is the entity that accesses the NFS server's resources. The client may be an application that contains the logic to access the NFS server directly. The client may also be the traditional operating system client that provides remote file system services for a set of applications. Server The "server" is the entity responsible for coordinating client access to a set of file systems and is identified by a server owner. Hellwig Expires January 9, 2017 [Page 2] Internet-Draft pNFS SCSI Layout for NVMe July 2016 2. SCSI Layout mapping to NVMe The SCSI layout definition [scsi-layout] only references few SCSI specific concepts directly. This document uses the NVMe SCSI Translation Reference document ([NVME-STLR]) to provide mappings from these SCSI concepts to NVM Express ([NVME]) concepts that SHOULD be used when using the pNFS SCSI layout with NVMe devices. The NVMe SCSI Translation Reference is used to define the NVMe command and concepts that SHOULD be used to implement the pNFS SCSI layout. Implementations MAY or MAY not use an actual SCSI to NVMe translation layer. 2.1. Volume Identification The SCSI layout uses the Device Identification VPD page (page code 0x83) from [SPC4] to identify the devices used by a layout. Section 6.1.4 of [NVME-STLR] explains how an an implementation SHOULD construct a valid Device Identification VPD page based on the NVMe Identify data. Only NVMe devices that support either the EUI64 or NGUID value in the Identify Namespace data SHOULD be used as storage devices for the pNFS SCSI layout, as the methods based on the Serial Number for legacy devices might not be suitable for unique addressing needs. 2.2. Client Fencing The SCSI layout uses Persistent Reservations to provide client fencing. For this both the MDS and the Clients have to register a key with the storage device, and the MDS has to create a reservation on the storage device. Section 6.7 of [NVME-STLR] contains a full mapping of the required PERSISTENT RESERVE IN and PERSISTENT RESERVE OUT SCSI command to NVMe commands which SHOULD be used when using NVMe devices as storage devices for the pNFS SCSI layout. 2.3. Volatile write caches The equivalent of the WCE bit in the Caching Mode Page in [SBC3] is the Write Cache Enable field in the NVMe Get Features command, see Section 6.3.3.2 of [NVME-STLR]. If a write cache is enable on a NVMe device used as a storage device for the pNFS SCSI layout, the MDS must ensure to use the NVMe FLUSH command to flush the volatile write cache. Hellwig Expires January 9, 2017 [Page 3] Internet-Draft pNFS SCSI Layout for NVMe July 2016 3. Security Considerations Since no protocol changes are proposed here, no security considerations apply. 4. IANA Considerations The document does not require any actions by IANA. 5. Normative References [NVME] NVM Express, Inc., "NVM Express Revision 1.2.1", July 2016. [NVME-STLR] NVM Express, Inc., "NVM Express: SCSI Translation Reference Revision 1.5", June 2015. [RFC2119] Bradner, S., "Key words for use in RFCs to Indicate Requirement Levels", March 1997. [SBC3] INCITS Technical Committee T10, "SCSI Block Commands-3", ANSI INCITS INCITS 514-2014, ISO/IEC 14776-323, 2014. [SPC4] INCITS Technical Committee T10, "SCSI Primary Commands-4", ANSI INCITS 513-2015, 2015. [scsi-layout] Hellwig, C., "Parallel NFS (pNFS) SCSI Layout", June 2016. Author's Address Christoph Hellwig Email: hch@lst.de Hellwig Expires January 9, 2017 [Page 4]